Xiaomi scales are some of the most popular smart gadgets for the home, but even they require periodic adjustment. If your Xiaomi electronic scales have begun to lie, show unstable values or refuse to turn on, the problem most often lies in the miscalibration. In this article, we will discuss how to correctly calibrate the Mi Scale 1/2, Xiaomi Smart Scale 2 and other models from preparation to verification of the result.
Calibration is not only necessary for obvious failures. Even new scales can yield an error of up to ยฑ0.1 kg due to transportation, temperature change or uneven surface. We will talk about three methods: automatic calibration through the application, manual adjustment with weights and reset to factory parameters. And also - what errors spoil the result and how to avoid them.
Why Xiaomi Libra Lies: 5 Top Reasons
Before you rush to calibrate, check that the problem is in the settings, not the hardware breakdown.-5 reasons for inaccurate statements:
- ๐ฆ Uneven surface: scales must be placed on a hard, flat surface (tile, laminate), carpet, linoleum or soft floor absorb vibrations of sensors.
- ๐ Settled battery: at a discharge below 20%, the scales begin to "glutch" - show different values when re-weighing.
- ๐ก๏ธ Temperature swings: if the scales are transferred from cold to heat (or vice versa), the sensors need 2-3 hours to adapt.
- ๐ฑ Application sync failure: Mi Fit or Zepp Life may not process data correctly if not updated.
- โ๏ธ Factory marriage of sensors: if the scales were lying from the first day and the calibration does not help - this is a reason for warranty repair.
Critical error: if the scales show Err, Lo, or flash all the indicators, it's not a calibration problem, it's a hardware failure.
How do you know if you need calibration? Weigh 3 times in a row at 10 seconds intervals. If the difference between readings is greater than 0.2 kg, it's time to adjust.
Calibration Preparation: What to Do Before Setup
The wrong preparation is the main reason why calibration fails.
Make sure the battery is charged (>50%).
Put the scales on a flat, solid surface (check the level).
Remove dust and dirt from sensors (use a dry soft brush).
Update the Mi Fit/Zepp Life app to the latest version.
Remove and insert the battery (to reset the cache).-->
Pay special attention to the surface. Even a slight inclination of 2-3 degrees can give an error of up to 0.5 kg. To check the levelness, put a glass of water on the scales - if the water is not parallel to the edge, the surface is uneven.
If you have a Xiaomi Smart Scale 2 with body composition measurement, don't weigh your bare feet before calibrating - the moisture on the sensors distorts the results.
โ ๏ธ Note: Do not use household weights (such as dumbbells or sugar bags) for calibration. Their real weight may differ from the specified by 5-10%, which will negate the setting. M1 or M2.
Method 1: Automatic calibration via Mi Fit/Zepp Life
The easiest way is to use the built-in calibration function in the official app, which is available for most models except the Mi Scale 1 (only manually set up).
Instructions for Mi Fit (similar to Zepp Life):
- Open the app and go to the scale profile (Devices โ Your scales โ Settings).
- Select Calibration (or Accuracy Settings in New Versions).
- Follow the hints on the screen: you usually need to stand on the scale and wait 5-10 seconds.
- After completion, check the readings with the reference load (for example, a water bottle of 1.5 liters = 1.5 kg).
If the application does not contain the item "Calibration", update the firmware of the scales:
Settings โ About the device โ Updating the firmware๐ก
After automatic calibration, reset the scales: take out the battery for 30 seconds, then insert back in. This will reset the temporary sensor errors.
| Model of weights | Supports auto-calibration? | Requires a reference cargo? |
|---|---|---|
| Mi Scale 1 | โ No. | โ Yes (10 kg) |
| Mi Scale 2 | โ Yes. | โ No. |
| Xiaomi Smart Scale 2 | โ Yes. | โ No. |
| Xiaomi Body Composition Scale 2 | โ Yes. | โ Yes (optional) |
Method 2: Manual calibration with weights (for power users)
If the automatic adjustment didnโt work, or if you have an old model without this feature, you will have to calibrate manually. You will need a reference load (better 10 kg, but 5 kg will do).
Step-by-step:
- Turn on the scales and wait for zeros (0.0).
- Carefully place the weight on the center of the platform (do not shift!).
- Press the on button for 5-7 seconds until the CAL (or flashing digits) appears.
- Wait 10-15 seconds โ the scales will retain new parameters and reboot.
- Check the accuracy: weigh the weight again. The error should not exceed ยฑ0.05 kg.
If after calibration the scales show Err:
- ๐ Repeat the procedure with another weight.
- ๐ Check the battery (voltage should be available) โฅ3.0V).
- ๐ฑ Update the firmware through Mi Fit.
โ ๏ธ Warning: Do not use objects weighing less than 3 kg for manual calibration - sensors will not be able to accurately calibrate under low load).
What if the scales are not in CAL mode?
Method 3: Reset to factory settings (hard reset)
If the calibration fails, the last chance is a complete reset, which will return the scales to the โout of the boxโ state, but will delete all stored data (user profiles, weighing history).
How to make a hard reset:
- Turn off the scales (press the button for 3 seconds).
- Remove the battery for 1 minute.
- Insert the battery back and hold the button for 15 seconds until the indicator flashes.
- Release the button and the scales will reset and reset.
After discharge:
- ๐ Tie the scales again in Mi Fit (Add device) โ Libra).
- ๐ฑ Update the firmware to the latest version.
- โ๏ธ Conduct automatic or manual calibration (see methods above).
Important: Some models (e.g. Xiaomi Smart Scale 2) are reset differently โ through the app:
Device Profile โ Settings โ Resetting settings๐ก
Factory reset should be the last option, and 80 percent of the time, conventional calibration or battery replacement helps.
Typical calibration errors and how to avoid them
Even when you follow instructions correctly, users often make mistakes that spoil the results.
- ๐ง Calibration on cold scales: if you just brought the scales from the street (temperature below) +10ยฐC, the sensors will be inaccurate. Let them heat up to room temperature.
- ๐ฃ Weighing in shoes or socks: for accurate calibration, you need to stand barefoot (but the platform must be dry!).
- ๐ Using the same weights to check: if the reference weight is inaccurate, you will fix the error.
- ๐ต Ignoring updates: outdated firmware can block calibration. Always update the software before setting up.
Another common problem is that the readings are unstable after calibration, and if the scales are right, then lie, check.
- ๐ Battery Contacts: Oxidation or Bad Contact Causes Voltage Spikes.
- ๐ถ Interference from other devices: Keep scales away from routers, microwaves and wireless speakers.
- ๐ง Wrong position: Stand on the scale so that the legs are symmetrically located relative to the center.
How to check accuracy after calibration
Calibration done, but how do you make sure the scales are now telling the truth? Here are 3 reliable ways to check:
- Reference weight test: weigh a weight of known weight (e.g. 10 kg) 5 times in a row, the difference between the readings should not exceed 0.03 kg.
- Cross check: compare your weights to those at a pharmacy or fitness club, with an error of ยฑ0.1 kg.
- Repeatability test: weigh 3 times at intervals of 1 minute. If the difference is more than 0.2 kg - calibration is unsuccessful.
For models with body composition analysis (Xiaomi Body Composition Scale 2), check the stability of impedance measurements:
- ๐ง Weigh your bare feet on a dry platform.
- ๐ Compare your fat/muscle percentage with data from another analyzer (e.g., gym).
- ๐ Repeat the measurement in 5 minutes - the indicators should differ by no more than 1-2%.
If after all the checks, the scales are lying anyway, there's probably a hardware problem.
- ๐ง Check the integrity of the sensors (if there are cracks in the glass).
- ๐ Contact the Xiaomi Service Center (the warranty is valid for 12 months from the date of purchase).